Free standard shipping on all orders to the contiguous 48 states

Currency

Your cart

Your cart is empty

Velleman LRS-75-12 ITE SWITCHING POWER SUPPLY - SINGLE OUTPUT - 75 W - 12 V

Regular price $29.99
Unit price
per
No Reviews

Velleman LRS-75-12 ITE SWITCHING POWER SUPPLY - SINGLE OUTPUT - 75 W - 12 V

Regular price $29.99
Unit price
per
No Reviews
Fast Shipping
Secure payment
(0 in cart)
100% Secure payments

Your details are protected and safe with us.

You may also like

About this item

Velleman LRS-75-12 ITE SWITCHING POWER SUPPLY - SINGLE OUTPUT - 75 W - 12 V

Velleman

Downloads

No files available.
Features
  • universal AC input / full range
  • withstands 300 VAC surge input for 5 seconds
  • no load power consumption < 0.3 W
  • miniature size and 1U low profile
  • high operating temperature up to 70°C
  • cooling by free air convection
  • operating altitude up to 5000 m
  • withstands 5G vibration test
  • high efficiency, long life and high reliability
  • 3 years warranty
  • protection against: short circuit / overload / overvoltage
  • 100% full load burn-in test
  • LED indicator for power ON
  • terminal block cover not included
  • for professional use only
  • This device must be installed by a qualified person.
Specifications
  • output:
-DC voltage: 12 V
-rated current: 6 A
-current range: 0-6 A
-rated power: 72 W
-ripple & noise (max.): 120 mVp-p
-voltage adj. range: 10.2-13.8 V
-voltage tolerance: ± 1.0 %
-line regulation: ± 0.5 %
-load regulation: ± 0.5 %
-setup, rise time:
   -500 ms, 30 ms / 230 VAC
   -500 ms, 30 ms / 115 VAC at full load
-hold up time (typ.):
   -60 ms / 230 VAC
   -12 ms / 115 VAC at full load
  • input:
-voltage range:
   - 85-264 VAC
   -120-373 VDC
   -withstands 300 VAC surge for 5 s
-frequency range: 47-63 Hz
-efficiency (typ.): 89 %
-AC current (typ.):
   -1.4 A / 115 VAC
   -0.85 A / 230 VAC
-inrush current (typ.): cold start 50 A / 230 VAC
-leakage current: < 0.75 mA / 240 VAC
  • protection:
-overload:
   -110-150 % rated output power
   -protection type: hiccup mode, recovers automatically after fault condition is removed
-overvoltage:
   -13.8-16.2 V
   -protection type: hiccup mode, recovers automatically after fault condition is removed
  • environment:
-operating temperature: -30 to +70 °C
-operating humidity: 20-90 % RH non-condensing
-storage: -40 to +85 °C, 10-95 % RH
-temperature coefficient: ± 0.03 %/°C (0-50 °C)
-vibration: 10-500 Hz, 5G 10 min/1 cycle, period for 60 min each along X, Y, Z axes
  • safety & EMC:
-safety standards: UL60950-1, TÜV EN60950-1 approved
-withstand voltage:
   -input to output: 3.75 kVAC
   -input to ground: 2 kVAC
   -output to ground: 1.25 kVAC
-isolation resistance: input to output, input to ground, output to ground: 100 Mohm / 500 VDC / 25 °C / 70 % RH
-EMC emission: compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3
-EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2), heavy industry level, criteria A
  • other:
-MTBF: min. 681,200 h, MIL-HDBK-217F (25 °C)
-dimensions: 99 x 97 x 30 mm
-weight: 300 g